Exercises and worked answers
Download the synthetic timeseries. Its values are invented for teaching, not generated by GROMACS.
Exercise 1 · RMSD
The backbone RMSD rises during the early part of a trajectory and later fluctuates around a narrower range. Does this alone show equilibration?
Worked answer
No. RMSD depends on reference and atom selections. A visually flatter segment alone does not establish equilibration, convergence or adequate sampling. Examine thermodynamic diagnostics, other structural observables and independent replicas, and define analysis windows.
Exercise 2 · Replicas
Two independent runs give similar mean RMSD but different loop RMSF. What should you do?
Worked answer
Inspect whether the loop samples distinct states or the difference reflects insufficient sampling, alignment, starting conditions or force-field behaviour. Extend or add independent sampling under a predeclared plan; report replicate variation instead of pooling away disagreement.
Exercise 3 · “Stable binding”
A ligand remains in the binding pocket for a 20-ns simulation. Does this prove high affinity?
Worked answer
No. Retention over a finite trajectory starting from a docked pose does not measure affinity, establish equilibrium binding or show that the pose is correct. It is a conditional observation under one model and sampling window.
Exercise 4 · Coordinate drift
Whole-protein RMSD is high, but the folded domain RMSD after fitting that domain is low. How might you interpret this?
Worked answer
Rigid-body movement of domains or different global orientations may contribute to whole-protein RMSD. Compare domain-wise and inter-domain measures; report fit and measurement selections. Do not label a high value as unfolding without inspecting structural changes.
Exercise 5 · Block means
Using the synthetic table, compare the first-five and last-five RMSD and Rg means. What inference is valid?
Worked answer
The arithmetic means are 0.206 vs 0.242 nm (RMSD) and 2.410 vs 2.402 nm (Rg). You may report these sample summaries for the supplied synthetic numbers only. The short sequence does not support any physical conclusion or convergence claim.
Suggested report
Provide system construction, force field, water/ion model, protonation/cofactor handling, minimisation/equilibration and production parameters, independent replicas, analysis selections and windows, diagnostics, uncertainty and limitations.